Abstract:
Basic theoretical concepts of static magnetic shielding are summarized. Expressions describing the magnetic field produced by a solenoidal coil confined coaxially inside a long thin ferromagnetic cylinder of constant permeability are derived. Conditions for the optimum arrangement of a magnetic screen for whole-body NMR systems are discussed. (C) 1989 Academic Press, Inc.
|