Authors: Kędzia P., Czechowski T., Baranowski M., Jurga J., Szcześniak E.

Title: Analysis of uniformity of magnetic field generated by the two-pair coil system

Source: Applied Magnetic Resonance

Year : 2013


Abstract:

In this paper we use a simple analysis based on properties of the axial field generated by symmetrical multipoles to reveal all possible distributions of two coaxial pairs of circular windings, which result in systems featuring zero octupole and 32 pole magnetic moments (six-order systems). Homogeneity of magnetic field of selected systems is analyzed. It has been found that one of the derived systems generates homogenous magnetic field whose volume is comparable to that yielded by the eight-order system. The influence of the current distribution and the windings placement on the field homogeneity is considered. The table, graphs and equations given in the paper facilitate the choice of the most appropriate design for a given problem. The systems presented may find applications in low field electron paramagnetic resonance imaging, some functional f-MRI (nuclear magnetic resonance imaging) and bioelectromagnetic experiments requiring the access to the working space from all directions.

DOI: 10.1007/s00723-012-0427-5   (Pobrane:  aktualizowanie)